We are using the XPAF software (Xerox) together with CA-Spool software (Broadcom) to print some thousands of reports (sysouts).
All works fine with XPAF V8 (or V9 or V10) running with CA-Spool V117 and CA-Spool V120, but with CA-Spool V140 we had a S0C1 Abend in any version of XPAF task.
......
DUMPID=004 REQUESTED BY JOB (XPAFXXX )
DUMP TITLE=COMPON=SSI,COMPID=5752SC1B6,ISSUER=IEFJSARR,MODULE=I
EFJSRE1,ABEND=S0C1,REASON=00000001,SNAME=ESF
IEA995I SYMPTOM DUMP OUTPUT 748
SYSTEM COMPLETION CODE=0C1 REASON CODE=00000001
TIME=10.15.03 SEQ=00122 CPU=0000 ASID=0029
PSW AT TIME OF ERROR 071C1000 80000002 ILC 2 INTC 01
Release : 14.0
Component : CA Spool
IBM made changes to the IAZFSVT control block with APARs OA54595 and OA56037.
The solution is to apply the related IBM PTFs according to the z/OS release.