GIMAPI ERROR: MMR0004S - An error occurred during msgget(). RC: 133
search cancel

GIMAPI ERROR: MMR0004S - An error occurred during msgget(). RC: 133

book

Article ID: 209049

calendar_today

Updated On:

Products

Mainframe Software Manager (Chorus Software Manager)

Issue/Introduction

When accessing the SMPE Environment tab you get an error message like this :

GIMAPI ERROR                                                                                                             
  Additional Diagnostic Data:                                                                                            
    An unknown error occurred.                                                                                           
      Attached Internal Log:    MMR0004S - An error occurred during msgget(). RC: 133 Reason: EDC5133I No space left on  

Environment

Release : 6.0

Component : Chorus Software Manager

Cause

CSM is running against JAVA parameter maximum values

Resolution

The error is :

MMR0004S - An error occurred during msgget(). RC: 133 Reason: EDC5133I No space left on Device 

Check with the console command D OMVS,L if there are any IPC* parameters running out of value... 
Check as specially the parameters IPCMSGNIDS and IPCSEMNIDS.