Spool

Issue/Introduction

Error stopping CA Spool"

 

OPS7914O SSM AUDIT: STCTBL.CASPOOL UPDATED by OPSOSF SSMSHUT DESIRED_STATE=DOWN

F CASPOOL,TNET                                                    

F CASPOOL,SHUTDOWN

State of CASPOOL is STOPPING     

ESF801  SHUTDOWN COMMAND ACCEPTED

ESF7033 Accept failed errno=122. EDC5122I Input/output error.                 

ESF7034 Setsockopt SO_REUSEADDR failed errno=113. EDC5113I Bad file descriptor.

Environment

Release : 12.0 14.0

Component : CA Spool

Cause

The TCPIP stack was shutdown before CA Spool.

Resolution

This error is occurring because the TCP/IP started task was stopped before CA Spool was stopped.

Recommended including the TCP/IP stack as a pre-requisite to CA Spool in the SSM table.