CAD8PROC abends with B78 RC=5C takes CAIW154E - SCHED/SC SUBSYSTEM ABEND
search cancel

CAD8PROC abends with B78 RC=5C takes CAIW154E - SCHED/SC SUBSYSTEM ABEND

book

Article ID: 208832

calendar_today

Updated On:

Products

Scheduler Smart Console Opera CA 7 Smart Console

Issue/Introduction

Migrated from z/OS 2.2 to z/OS 2.4 which does NOT support this parameter ALLOWUSERKEYCSA(YES)

So what do we have to change or reconfigure in Smart Console to fix the B78 error

 

622 SYSTEM COMPLETION CODE=B78 REASON CODE=0000005C

 

 

5C

A program attempted to obtain or release user-key (8 - 15) storage from

a CSA subpool but the ALLOWUSERKEYCSA(NO) parameter is specified in a

DIAGxx member of PARMLIB and either of the following conditions is true:

Here's the STC error:

*CAIW002I SCHED/SC Subsystem Termination Complete

IEA705I ERROR DURING GETMAIN SYS CODE = B78-5C CAD8PROC CAD8P

IEA705I 00FC2500 008F80E0 008F80E0 00F11000

IEA995I SYMPTOM DUMP OUTPUT 622

SYSTEM COMPLETION CODE=B78 REASON CODE=0000005C

TIME=10.50.16 SEQ=00241 CPU=4000 ASID=006C

PSW AT TIME OF ERROR 070C1000 813F2190 ILC 2 INTC 0D

NO ACTIVE MODULE FOUND

 

 

Environment

Release : 1.1

Component : Scheduler/Smart Console for OS/390,  7 / Smart Console, CA Opera

Resolution

The problem is with the common component utilized between Scheduler, Opera, and 7 Smart Console.

APAR RO77906 goes against this common component. APPLY this APAR and its related PRE requirements as well.

QO85889, QO91580, RO09220, RO27899, RO77906

Additional Information

The APAR RO77906 can be found under Opera for z/OS when searching for the APAR itself.