IDB2 DBG72017E message id shows only once in one environment but twice in another environment
search cancel

IDB2 DBG72017E message id shows only once in one environment but twice in another environment

book

Article ID: 208791

calendar_today

Updated On:

Products

SYSVIEW Performance Management Option for DB2 for z/OS Database Management for DB2 for z/OS - Performance Suite

Issue/Introduction

Using SYSVIEW for db2 to generate WTO exception  and  DBG72017E for escalation purposes

The exception is 

High percentage of maxium REMOTE threads in use   
during the last exception interval =&VALUEXX%      

But was slightly modified to

SLF High percentage of MAX REMOTE threads in use   
during the last exception interval =&VALUEXX%  

It shows only once in one environment but twice in another environment.  Is there a specific parameter for duplicate message ID behavior?

 

Environment

Release : 20.0

Component : CA SYSVIEW Performance Management Option for DB2 for z/OS

Resolution

 Change the S to M on the WTO message in Logging and Notification Controls panel for the exceptions.