AlarmNotifier not showing EXTRA_ATTRS_AS_ENVVARS

book

Article ID: 208093

calendar_today

Updated On:

Products

CA Spectrum

Issue/Introduction

 Attempting to configure attributes from the alarm notifier without success
I've configured the .alarmrc with the following attributes :

EXTRA_ATTRS_AS_ENVVARS=0x12bfb,0x12bfd

corresponding respectively to USER_AssetTag and USER_AssetOwner attributes that have values 'linux prod' and 'gr_linux'

But when the variables are echoed, $SANM_0x12bfb and $SANM_0x12bfd, both values are 'N/A'

 

Environment

Release : 20.2

Component : Spectrum Core / SpectroSERVER

Resolution

 The USER_AssetTag (0x12bfb) and USER_AssetOwner (0x12bfd) attribute IDs are not available on the ProcMon2790 process model.  

 

In order to see these attributes displayed on the AlarmNotifier, the ProcMon2790 alarm should be generated on the Device Model instead of Process Model.