TRAC179I DB ERROR: CMD=OPEN ,TBL=EVT,RET CD=25,INT RC=14 may occur if the DBID for Jobtrac
is not defined to Datacom.
Release : 11.0
Component : JOBTRAC
The return code of CD=25,INT RC=14 in the TRAC179I message indicates the following:
INVALID DATABASE ID
If the request was an OPEN, the User Requirements Table being opened probably references a database
which is not defined to the Directory. The database is either in the user URT or is a system database.
System databases are defined in the MUF startup options.
This will occur if the DBID for Jobtrac has not been defined to Datacom. The STAGE2 job can be used
to define the 161 and 162 DBIDs to Datacom.