The Common Services SMP/E APPLY and ACCEPT jobs for legacy products, CCS30APB and CCS40ACB end with RC=04. Is this a problem?
The errors are:
Job CCC30APB
Many warnings like this for different modules:
GIM23913W LINK-EDIT PROCESSING FOR SYSMOD CDU4E00 WAS SUCCESSFUL FOR MODULE DSX IN LMOD CA$DSXXX IN THE CCCSLOAD
LIBRARY. THE RETURN CODE WAS 04. DATE 21.035 - TIME 15:51:43 - SEQUENCE NUMBER 000043 - SYSPRINT FILE
SMP00043.
GIM20501I APPLY PROCESSING IS COMPLETE. THE HIGHEST RETURN CODE WAS 04.
IEW2651W 511C ESD AMODE 24 CONFLICTS WITH USER-SPECIFIED AMODE 31 FOR ENTRY POINT
Job CCS40ACB
GIM24701W SMP/E COULD NOT OBTAIN LINK-EDIT PARAMETERS FOR LOAD MODULE EARLOPT FOR SYSMOD CXE6100. DEFAULTS WERE USED.
GIM20501I ACCEPT PROCESSING IS COMPLETE. THE HIGHEST RETURN CODE WAS 04.
Release : 15.0
Component : CCS390 - COMMON SERVICES FOR Z/OS
The RC=04 is caused by warning messages which are acceptable and can be ignored.