Running with SYSVIEW Release CICS/TS, while reviewing statistics using CSYSDATA, in certain intervals "Transactions monitored" field is always 1 for CICS regions. Is this because of an incorrect configuration?
Jobname Date Time Trans Lifetime CPUTime IOCount
C152T021 2020/12/22 16:00:00 1 0.003965 0.003858
C152M021 2020/12/22 16:00:00 1 0.002461 0.002095 762
C152M022 2020/12/22 16:00:00 1 0.002413 0.002196 1008
C152E022 2020/12/22 16:00:00 1 0.002222 0.002085
C152A02A 2020/12/22 16:00:00 1 0.002663 0.002453 12061
C152A028 2020/12/22 16:00:00 1 0.002493 0.002393 7886
C152A025 2020/12/22 16:00:00 1 0.002488 0.002402 153357
C152A027 2020/12/22 16:00:00 1 0.002743 0.002431 7716
C152A029 2020/12/22 16:00:00 1 0.003997 0.002448 2979
C152E022 2020/12/22 16:15:00 1 0.002141 0.002086
C152M022 2020/12/22 16:15:00 1 0.002250 0.002120 939
C152T021 2020/12/22 16:15:00 1 0.004195 0.003991
C152A029 2020/12/22 16:15:00 1 0.002557 0.002428 546
The CSYSDATA transaction count shows monitored transaction counts within the current interval. So that value is reset at the end of the interval, which here appears to be 15 minutes.
The CICS total transaction count shown in the display is the value of total transactions whether they were monitored or not, that have occurred since last start of SYSVIEW, or if a reset was issued. The CICS interval transactions would be all transactions within the current interval, monitored or not.