When running job BDACTDD2 to upgrade CA Datacom/DB to Version 15.1, STEP2B ends with CC 16 and produces these errors:
PAGE.. ERROR.......... MESSAGE.....
16 DDPNTF0002 NOT FOUND
17 DDPNTF0002 NOT FOUND
18 DDPNTF0002 NOT FOUND
19 DDPNTF0002 NOT FOUND
END OF RECAP REPORT
*-----------------------------------------------------------
* -UPG DATABASE,AUTOSTATUS(PROD)
*-----------------------------------------------------------
FUNCTION = UPDATE-ENTITY
ENTITY-TYPE = DATABASE
OCCURRENCE = AUTOSTATUS
VERSION = PROD
**** ERROR **** RETURN CODE = DDPNTF0002 NOT FOUND
*-----------------------------------------------------------
* .........................*** ERRORS NOT PROCESSED ***..
*-----------------------------------------------------------
* -UPG DATABASE,AUTOCOLLECT-SNAPTABLES(PROD)
*--------------------------------------------
FUNCTION = UPDATE-ENTITY
ENTITY-TYPE = DATABASE
OCCURRENCE = AUTOCOLLECT-SNAPTABLES
VERSION = PROD
**** ERROR **** RETURN CODE = DDPNTF0002 NOT FOUND
ERRORS DETECTED, NO MAINTENANCE APPLIED
*-------------------------------------------------
* -UPG DATABASE,AUTOCOLLECT-DELTATABLES(PROD)
*-------------------------------------------------
FUNCTION = UPDATE-ENTITY
ENTITY-TYPE = DATABASE
OCCURRENCE = AUTOCOLLECT-DELTATABLES
VERSION = PROD
**** ERROR **** RETURN CODE = DDPNTF0002 NOT FOUND
*-------------------------------------------------
ERRORS DETECTED, NO MAINTENANCE APPLIED
*---------------------------------------------
* -UPG DATABASE,CA_CDC_BASE(PROD)
*---------------------------------------------
FUNCTION = UPDATE-ENTITY
ENTITY-TYPE = DATABASE
OCCURRENCE = CA_CDC_BASE
VERSION = PROD
**** ERROR **** RETURN CODE = DDPNTF0002 NOT FOUND
*---------------------------------------------
Release : 15.1
Component : CA DATACOM/DB
These errors result from the subject databases not being present in the upgraded Datadictionary.
In general, these messages might not be a problem. The errors are the result of using an upgrade command on databases that are optional and that appear to not be in use in this system.
If not using AUTOSTATUS, AUTOCOLLECT, or CDC (Change Data Capture) in this MUF, then you can continue on and ignore these errors.
As always, please contact Broadcom support for CA Datacom if you have further questions.