RC=X'04', DETECTED AT OPSMMG+X'000007EE' when accessing the OPS/MVS PARMS panel =4.1.1
search cancel

RC=X'04', DETECTED AT OPSMMG+X'000007EE' when accessing the OPS/MVS PARMS panel =4.1.1

book

Article ID: 207452

calendar_today

Updated On:

Products

OPS/MVS Event Management & Automation

Issue/Introduction

When I try to get into =4.1.1, receives below error.

 

            GET OF 3890336 BYTES IN SUBPOOL X'00' ERROR RC=X'00000004' REQUESTED BY   OPSMM

G+X'000798'                                                                        

            MESSAGE QUEUE GETMAIN FAILED, RC=X'04', DETECTED AT OPSMMG+X'000007EE'                

            ALLOCATION OF EXTERNAL DATA QUEUE FAILED, RC=4                                       

            ***                                                                                 

 

Environment

Release : 13.5

Component : OPS/MVS

Resolution

This error typically occurs when the value for REXXMAXQUEUE is set to high.   Recommend lowering the value.