SSP-S410/SSP-S210 Chassis light is yellow or amber
search cancel

SSP-S410/SSP-S210 Chassis light is yellow or amber

book

Article ID: 207004

calendar_today

Updated On:

Products

SSP-S410 PLATFORM ISG Proxy ISG Content Analysis

Issue/Introduction

Chassis light is yellow or amber

Environment

SSP-S410

SSP-S210

Cause

Chassis intrusion detection

Resolution

Serial access is required to interrupt the boot sequence. Click here for serial console instructions for the SSP. This has changed compared to ProxySG hardware. Please confirm the right cable is available before any trip is made to a data center.

Make sure the lid is closed
Connect to the serial console as noted above
While booting you will see the default operating system.  Press the space bar during the 5 second pause
Boot into diags ('d' from the bootloader menu)
Run the command 'clear intrusion'
Reboot
Confirm the Chassis light is now green