VAN0901I GENSVC99 An SVC 99 error has occurred in dynamic allocation.
search cancel

VAN0901I GENSVC99 An SVC 99 error has occurred in dynamic allocation.

book

Article ID: 206921

calendar_today

Updated On:

Products

Vantage Storage Resource Manager

Issue/Introduction

Getting the following error during BVIR processing:

GENSVC99 An SVC 99 error has occurred in dynamic -- allocation.
 16.00.03 STC08739  VAN0901I GENSVC99 ---- DSNAME=SYSS.SVM.BVIR.DATA
 16.00.03 STC08739  VAN0901I GENSVC99 ---- DISP=NEW
 16.00.03 STC08739  VAN0901I GENSVC99 ---- MGMTCLAS=TAPESYNC
 16.00.03 STC08739  VAN0901I GENSVC99 ---- UNIT=TAPEC
 16.00.03 STC08739  VAN0901I GENSVC99 IKJ56225I DATA SET SYSS.SVM.BVIR.DATA ALREADY IN USE, TR
 16.00.03 STC08739  VAN0901I GENSVC99 Y LATER+
 16.00.03 STC08739  VAN0901I GENSVC99 IKJ56225I DATA SET IS ALLOCATED TO ANOTHER JOB OR USER
 16.00.03 STC08739  VAN0901I GENSVC99 IEFA110I DATA SET CONTENTION
 16.00.03 STC08739  VAN0901I GENSVC99 DATA SET SYSS.SVM.BVIR.DATA IN USE BY
 16.00.03 STC08739  VAN0901I GENSVC99 SYSNAME  JOBNAME  ASID
 16.00.03 STC08739  VAN0901I GENSVC99 NWRP    SAMS     00D8
 

Environment

Vantage

Resolution

The BVIR scripts need to run on one LPAR. In this case, 2 LPARS were sharing the same Vantage. Both LPARs were trying to execute the same script at the same time. This was causing the DATA ALREADY IN USE error. Add an SYSID= to the script so it will only execute on one LPAR.