IDB2 Datacollector received an abend S206-10 when starting up
search cancel

IDB2 Datacollector received an abend S206-10 when starting up

book

Article ID: 206827

calendar_today

Updated On:

Products

SYSVIEW Performance Management Option for DB2 for z/OS Database Management for DB2 for z/OS - Performance Suite

Issue/Introduction

Datacollector abended with the following message:
IEA995I SYMPTOM DUMP OUTPUT  315
                SYSTEM COMPLETION CODE=206  REASON CODE=00000010
                  TIME=17.45.36  SEQ=04349  CPU=0000  ASID=003A
                  PSW AT TIME OF ERROR  070C1000   8106552A  ILC 2  INTC 0D
                   NO ACTIVE MODULE FOUND
                    NAME=UNKNOWN
                    DATA AT PSW  01065524 - 8400181E  0A0D18FB  180C181D
                    GR 0: 00001F00   1: 84206000
                       2: 00000000   3: 00000000
                       4: 00000000   5: 008FF7C8
                       6: 000000FF   7: 00000000
                       8: 7F6530B0   9: 01065A50
                       A: 00000000   B: 00000000
                       C: 00000000   D: 7F6530B0
                       E: 84206000   F: 00000010




Environment

Release : 20.0

Component : CA SYSVIEW Performance Management Option for DB2 for z/OS

Resolution

Make sure that the CDBALOAD is APF authorized.