The following abend occurred during a requested shutdown of the xmanager task
DETECTOR TERM IN PROGRESS FOR DB2=DBT6 USER=CONSOLE
DYNAMIC COLLECTION S13E ABEND INCURRED/TERMINATION FORCED
DETECTOR TERM CLEANUP IN PROGRESS DB2=DBT6
DETECTOR TERM CLEANUP COMPLETE DB2=DBT6
DETECTOR COLLECTION INTERVAL END TIME=15:15 INTERVAL=01:00 DB2=DBT6 VCAT=DBT6S
DATASTORE=DATASTOR REL=20
ERROR DURING FREEMAIN SYS CODE = 378-14 PDTT02DB PDTT02DB 00
00F61280 008B32F8 008B32F8 00000300 0000FFE0 2B721000
PDTT02DB ESTIMATE EXCEEDED BY 1,050,000 KBYTES
PDTT02DB ESTIMATE EXCEEDED BY 1,100,000 KBYTES
PDTT02DB ESTIMATE EXCEEDED BY 1,150,000 KBYTES
PDTT02DB ESTIMATE EXCEEDED BY 1,200,000 KBYTES
PDTT02DB ESTIMATE EXCEEDED BY 1,250,000 KBYTES
PDTT02DB ESTIMATE EXCEEDED BY 1,300,000 KBYTES
PDTT02DB ESTIMATE EXCEEDED BY 1,350,000 KBYTES
PDTT02DB ESTIMATE EXCEEDED BY 1,400,000 KBYTES
PDTT02DB ESTIMATE EXCEEDED BY 1,450,000 KBYTES
PDTT02DB ESTIMATE EXCEEDED BY 1,500,000 KBYTES
PDTT02DB ESTIMATE EXCEEDED BY 1,550,000 KBYTES
SVC DUMP HAS CAPTURED: 284
71 REQUESTED BY JOB (PDTT02DB)
LE=CA/XMANAGER 20.0 DUMP LOC: *UNKNOWN+N/A ABEND:
SYMPTOM DUMP OUTPUT 285
OMPLETION CODE=378 REASON CODE=00000014
.15.36 SEQ=28330 CPU=0000 ASID=0052
TIME OF ERROR 070C1000 81382472 ILC 2 INTC 0D
TIVE MODULE FOUND
S0C1 PSW: 070C3000 80000004 PRD: PDT DB2: DBT6
UNKNOWN
AT PSW 0138246C - 00181610 0A0D18CE 18FB180C
0: 00000000/00000000_84000000 1: 00000000/00000000_84378000
2: 00000000/00000000_0000FFE0 3: 40000000/00000050_00000003
4: 00000000/00000000_008B32F8 5: 00000000/00000000_008B8828
6: 00000000/00000000_8137E708 7: 00000000/00000000_00F61280
8: 00000000/00000000_00000000 9: 00000000/00000000_0000FFE0
A: 00000000/00000000_2B721000 B: 00000000/00000000_7F3FB2E0
C: 00000000/00000000_00004006 D: 00000000/00000000_2B60712C
E: 00000000/00000000_2B6FF102 F: 00000001/00000000_00000014
SYMPTOM DUMP
Release : 20.0
Component : CA Detector for DB2 for z/OS
The abend S378-14 will occur if one, or more, Detector collection cleanups were queued, with message PDT0731, and the xmanager started task was stopped and then restarted before restarting Detector collections. When Detector collection startup attempts to complete
the queue cleanup and tries to free storage that was already released when the xmanager task terminated resulting in abend S378-14.