SARBCH /DEFUSER was run with "/DEFUSER USER=xxxxxxx ACC=YYYYY MODE=ALL MASTER=Y", which resulted with error "SARBCU19 Access mode indicators invalid".
Release : 14.0
Component : CA View
In View 14.0, with the inclusion of JOB mode, the SARBCH /DEFUSER ACC=xxxxxx field should contain 6 values.
Having only 5 values will result in a SARBCU19 error.
Suggested that the field have a value added, so as to have 6 values, and the next attempt at the function was successful.