SYSVIEW r16 abends - s013-20 Abend. SYSPRINT
Job contains the following SYSPRINT DD:
//SYSPRINT DD DSN=UTL.CPFP.CICSPRDE.SYSPRINT.TEMP1,DISP=(SHR,PASS),
// RECFM=FB,LRECL=133,BLKSIZE=27920
Release : 16.0
Component : SYSVIEW
The block size is not a multiple of record length
An OPEN macro instruction was issued for a sequential data set using queued access. BLKSIZE is not a multiple of LRECL, or LRECL is 0 with RECFM=FB or RECFM=FBS, or BLKSIZE is not at least four bytes greater than LRECL with RECFM=V.
Changing the BLKSIZE to be 27930 or any other multiple of 133 (the LRECL in this example)
https://www.ibm.com/support/knowledgecenter/SSLTBW_2.4.0/com.ibm.zos.v2r4.ieam700/ee141i.htm