Since the last upgrade to CARS Level 2010 the following error message appears in Vantage STC log:

VAN0017E Parameter AUDITERR exceeds max length and will be truncated. Value 01-03-04-08-10-11-14

The parameter was not changed and is set to "AUDITERR (01-03-04-08-10-11-14-17-18-99)". According to the manual this is the default value. Nevertheless an error message is issued and the parameter is shortened?

 

Environment

Release : 14.0

Component : CA Vantage Storage Resource Manager

Resolution

The AUDITERR parameter changed its default and acceptable values as a part of PTF SO13209.

https://support.broadcom.com/download-center/solution-detail.html?aparNo=SO13209&os=z%2FOS