DBG37006E MIB 19:30:05 DB2 CALL FOR IFI CALL RESULTED IN FRB RETCODE 0100 AND FRB REASON CODE 00F30018
search cancel

DBG37006E MIB 19:30:05 DB2 CALL FOR IFI CALL RESULTED IN FRB RETCODE 0100 AND FRB REASON CODE 00F30018

book

Article ID: 203945

calendar_today

Updated On:

Products

SYSVIEW Performance Management Option for DB2 for z/OS Database Management for DB2 for z/OS - Performance Suite Database Management for DB2 for z/OS - SQL Performance Suite Insight Performance Monitor for DB2 UDB for z/OS Database Management for DB2 for z/OS - Administration Suite Database Management for DB2 for z/OS - Recovery Suite Database Management for DB2 for z/OS - Utilities Suite

Issue/Introduction

CA Datacollector Started task IDB2DCSC job abends daily at a particular time(19:30 PST) in Production.

Below is the Information found from DBGPRINT                                                                          
DBG43004I MIB  19:30:05 IFI FUNCTION READA    COMPLETED WITH RETURN CODE 0100 AND REASON CODE 00F30018
DBG37006E MIB  19:30:05 DB2 CALL FOR TERMINATE THREAD RESULTED IN FRB RETCODE 0100 AND FRB REASON CODE 00F30018
DBG37005I MIB  19:30:05 DATA COLLECTOR DISCONNECTED FROM DB2 SUBSYSTEM MIB     
                                                                               
DBG39038I MIB  19:30:05 TERMINATION STARTED FOR DATA COLLECTOR FOR DB2 SUBSYSTEM MIB
DBG84003I MIB  19:30:05 HEALTH CHECKER SUBTASK TERMINATING                     
DBG84004I MIB  19:30:05 HEALTH CHECKER SUBTASK TERMINATION COMPLETE            

                                                                               
  

Environment

Release : 20.0

Component : CA SYSVIEW Performance Management Option for DB2 for z/OS

Resolution

The Data Collector userID needs to be granted EXECUTE on the CA-Insight explain plan, referenced in the PLANSxx member of the CDBAPARM. The IDGRANT in the .SOURCE library contains a sample GRANT EXECUTE statement. 
See the following link for more about it. Security/db2-authorizations

Notes: Pay attention to whether initialization completed or not. The run time will be less than a minute if the IDGRANT was not done generally and the return and reason codes would have to match the one in the problem description.