SYSVIEW: not able to invoke the panels
search cancel

SYSVIEW: not able to invoke the panels

book

Article ID: 203931

calendar_today

Updated On:

Products

SYSVIEW Performance Management

Issue/Introduction

Cannot invoke SYSVIEW panels after back out the upgrade from V16 to V14.2 and receiving the below error running the TSO SYSV command: 

GSVX554E System parmlib read for member failed, SSID GSVX member GSVXGSVX      
GSVX529E IEFPRMLB failed, rc 0000000C rsn 00000001                             
GSV2328E Read SYSPARM member SYSTEM.PARMLIB.LIST(GSVXGSVX) failed. Member not found                                                                            

Environment

SYSVIEW 15.0 & 16.0 - z/OS supported releases - 

 

Resolution

Using the default SSID  as EU00 and the GSVBSSID module updated with EU00 was missing.

Putting the updated module into LINKLIST and TSO SYSV started working fine and getting SYSVIEW panels.