Under normal TSO edit the EJCK macro works.
When entering BMCs IOA via the TSO IOA command and then go into EDIT mode under the Control-M interface the EJCK macro hangs on the
ISPEXEC SELECT PGM(CAZ1JCKM) PARM('JCKOPT: RUNT SYN NOSEC USER(CV10PXS) EDCH
KSL NOREM RES(CTM,CV10PXS.JCLCHECK.OPTIONS,CTMPRINT) ')
It works without the CTM option being selected, just hangs when it is selected
This worked ok under the previous version (V8) but not the new Control-M version (V9) which was recently upgraded.
Release : 12.0
Component : CA JCLCheck workload Automation
BMC fix for Control-M (PTF number: PG05213 ) fixed the problem