CA JCLCHECK - Unable to execute EJCK when in BMC IOA using EDIT (Control-M)
search cancel

CA JCLCHECK - Unable to execute EJCK when in BMC IOA using EDIT (Control-M)

book

Article ID: 203726

calendar_today

Updated On:

Products

JCLCheck Workload Automation UNICENTER JCLCHECK COMMON COMPONENT

Issue/Introduction

Under normal TSO edit the EJCK macro works.

When entering BMCs  IOA via the TSO IOA command and then go into EDIT  mode under the Control-M interface the EJCK macro hangs on the  

 ISPEXEC SELECT PGM(CAZ1JCKM) PARM('JCKOPT: RUNT SYN NOSEC USER(CV10PXS)    EDCH

KSL NOREM RES(CTM,CV10PXS.JCLCHECK.OPTIONS,CTMPRINT)  ')    

 

It works without the CTM option being selected, just hangs when it is selected

This worked ok under the previous version (V8) but not the new Control-M version (V9) which was recently upgraded. 

 

 

                   

Environment

Release : 12.0

Component : CA JCLCheck workload Automation

Resolution

BMC fix for Control-M (PTF number: PG05213 ) fixed the problem