MONS--025 Error in VMWare probe configuration when expanding the resource
search cancel

MONS--025 Error in VMWare probe configuration when expanding the resource

book

Article ID: 203683

calendar_today

Updated On:

Products

DX Unified Infrastructure Management (Nimsoft / UIM)

Issue/Introduction

Environment:

ppm probe 3.51 on the UIM Server (primary hub)

ppm probe 3.50 on the secondary hub

vmware probe installed under the secondary hub

 

Expanding the source in the vmware probe configuration fails with error code MONS-025

Error captured on the ppm.log from the secondary hub

ppm] stdout: 16:30:14.969 [attach_socket] DEBUG c.nimsoft.ids.ctd.graph.CtdGraphBase - CtdAction is deprecated for instance graph usage. It has been replaced with CtdEntityDefinition in the scheme.
ppm] stdout: 16:30:14.971 [attach_socket] DEBUG c.nimsoft.ids.ctd.graph.CtdGraphBase - CtdAction is deprecated for instance graph usage. It has been replaced with CtdEntityDefinition in the scheme.

 

Environment

Release : 9.2.0

Component : UIM - PPM

Resolution

1. Deactivate the ppm probe on the Primary and secondary hub

2. Delete the "\Nimsoft\probes\service\ppm\cache" on each Hub

3. Deploy ppm 3.51 on the secondary hub ( same version as Primary hub)

4. Activate the ppm probe on the Primary and secondary hub