cdm probe bind failed 125
search cancel

cdm probe bind failed 125

book

Article ID: 203076

calendar_today

Updated On:

Products

DX Unified Infrastructure Management (Nimsoft / UIM)

Issue/Introduction

One of my target server's cdm probe unable to start.

In controller log:

Max. restarts reached for probe 'cdm' (command = cdm)

In cdm log:

Oct 19 13:25:30:018 [0001] cdm: cdm 6.42HF
Oct 19 13:25:30:018 [0001] cdm: Nimsoft Corporation
Oct 19 13:25:30:019 [0001] cdm: sockServer: bind failed 125
Oct 19 13:25:30:019 [0001] cdm: nimSession - failed to create server session on port 0, error code 125
Oct 19 13:25:30:019 [0001] cdm: nimSession failed
Oct 19 13:25:32:138 [0001] cdm: MC673968 pHostInfo->pchHostname soldu45-iu
Oct 19 13:25:32:138 [0001] cdm: MC673968 pHostInfo->pchMachineType sun4v
Oct 19 13:25:32:138 [0001] cdm: MC673968 pHostInfo->pchOsName SunOS
Oct 19 13:25:32:138 [0001] cdm: MC673968 pHostInfo->pchOsRelease 5.11
Oct 19 13:25:32:138 [0001] cdm: MC673968 pHostInfo->pchOsVersion 11.4.xx.xx.x

what is error code 125?

Environment

Release : 20.1

Component : UIM - CDM WITH IOSTAT

OS: Solaris 11

robot version: 7.93

cdm version: 6.42HF

Resolution

- cdm version 6.50-HF4

- Changed first_probe_port in controller to 48010.