SYMP919S END OF FILE ENCOUNTERED FOR INPUTT DURING PHASE 1 OF POST-PROCESSOR DRC = 0 .
search cancel

SYMP919S END OF FILE ENCOUNTERED FOR INPUTT DURING PHASE 1 OF POST-PROCESSOR DRC = 0 .

book

Article ID: 202269

calendar_today

Updated On:

Products

InterTest - CICS InterTest - Batch

Issue/Introduction

InterTest Batch 11.0.
SYMP919S error by IN25SYMP. PL/I is V1R5M1.

SYMP919S END OF FILE ENCOUNTERED FOR INPUTT DURING PHASE  1 OF POST-PROCESSOR  DRC =    0 .

Compile option is 

-OPTIONS SPECIFIED
0OBJ,X(F),M,A(S),OF,OP,MAP,STG,AG,NEST,LIST,NIS,S,NOPT,LIMITS(NAME(31)),FLAG(W),NODECK;
0IEL0003I          THE FOLLOWING STRING IS NOT RECOGNIZED AS A VALID OPTION KEYWORD AND IS IGNORED -- LIMITS
-OPTIONS USED

 AGGREGATE      NOCOUNT        ATTRIBUTES(SHORT)
 LIST           NODECK         CHARSET(60,EBCDIC)
 LMESSAGE       NOESD          NOCOMPILE(S)
 MACRO          NOFLOW         FLAG(W)
 MAP            NOGONUMBER     LINECOUNT(55)
 NEST           NOGOSTMT       MARGINS(2,72,0)
 OBJECT         NOGRAPHIC      SEQUENCE(73,80)
 OFFSET         NOIMPRECISE    SIZE(6847364)
 OPTIONS        NOINCLUDE      NOSYNTAX(S)
 SOURCE         NOINTERRUPT    XREF(SHORT)
 STMT           NOINSOURCE
 STORAGE        NOMARGINI
                NOMDECK
                NONUMBER
                NOOPTIMIZE
                NOTERMINAL

Environment

Release : 11.0

Component : CA InterTest Batch

Resolution

Required PL/I Options

The following compiler options are required to load symbolic information for PL/I programs when using the OS PL/I or IBM
PL/I for MVS and VM compiler:

AGGREGATE
ATTRIBUTES(FULL)
MAP
NEST
NOGONUM
NONUMBER
OPTIONS
SOURCE
STMT or GOSTMT
STORAGE
XREF(FULL)

Specify ATTRIBUTES(SHORT) and XREF(SHORT) may cause the error.
A(F) and X(F) are required.

The following compiler options are required to load symbolic information for PL/I programs when using Enterprise PL/I for
z/OS or Visual Age PL/I:
AGGREGATE
ATTRIBUTES(FULL)
LIMITS(NAME(31))
LIST
MAP
NATLANG(ENU)
NEST
NOGONUM
NOSTMT
NUMBER
OPTIONS
SOURCE
STORAGE
XREF(FULL)