When setting up an x86 MOI system with the V2.0.06 Validation ISO, during testing there were no alerts created.
Release : 2.0
Component : MF OPERATIONAL INTELLIGENCE
During the customization of the minimum threshold settings in the AlarmSuppressor.csv there was a blank line left in the file..
This is causing a stop to send alerts in MOI.
Remove the blank line(s) from the alarmSuppression.csv file and the alerting should resume.