UIM Upgrade fails with "Failed to stop monitors running in the UIM Server instance"
search cancel

UIM Upgrade fails with "Failed to stop monitors running in the UIM Server instance"

book

Article ID: 202013

calendar_today

Updated On:

Products

DX Unified Infrastructure Management (Nimsoft / UIM) CA Unified Infrastructure Management On-Premise (Nimsoft / UIM) CA Unified Infrastructure Management SaaS (Nimsoft / UIM)

Issue/Introduction

UIM upgrade fails during the "Run Upgrade Preparation" phase with error:  "Failed to stop monitors running in the UIM Server instance"

Error in Spanish installation: "Se ha producido un error al detenter los monitores que se están ejecutando en la instancia de DX Unified Infrastructure Management Serrver"

Environment

  • Release: UIM 20.3 / 20.4
  • Component: INSTALLATION

Cause

  • This issue is sometimes seen when a core probe is not activated prior to running the upgrade.

Resolution

  • Activate the distsrv probe before executing the upgrade.