TSS CREATE USING doesn't copy SCOPEd acids
search cancel

TSS CREATE USING doesn't copy SCOPEd acids

book

Article ID: 201923

calendar_today

Updated On:

Products

Top Secret

Issue/Introduction

TSS CREATE(acid2) USING(lsca_acid1)

to copy an LSCA, does not copy SCOPEd acids to the new acid.

Resolution

TSS CREATE USING has limitations and does not copy all information from the model ACID. For a TSS CREATE command, the model ACID information that is available from a TSS LIST(modelacid) DATA(BASIC,TSO) command is copied to the ACID, along with the INSTDATA, TSO DFLT, SMS, CICS, OMVS, and WORKATTR DATA information.

Note: Top Secret also copies the password information; however, Top Secret does not copy any PHRASE that is assigned to the ACID. Information that is not copied by CREATE USING (such as PERMITs) must be explicitly granted to the new ACID after the CREATE. To determine which information you need to grant, use the COMPARE command to compare the two ACIDs.