Sysview or Db2 data collector terminates at startup with a S0D3-13 abend in NSIGHTDC
search cancel

Sysview or Db2 data collector terminates at startup with a S0D3-13 abend in NSIGHTDC

book

Article ID: 201710

calendar_today

Updated On:

Products

SYSVIEW Performance Management Option for DB2 for z/OS

Issue/Introduction

The Sysview Performance Management Option for Db2 for z/OS (IDB2) data collector terminates at startup with an abend S0D3-13 in the NSIGHTDC module. 

07:57:08  CCSR010E NMSPRMVC S0D3 at 20A02E30 LMOD NSIGHTDC CSECT NADCFUNM +0019
07:57:08  CCSR021I OWNER = CA SYSVIEW for DB2 R20.0

Cause

The S0D3-13 abend in NSIGHTDC was caused by an unsuccessful start of the CA GSS address.  

Resolution

The successful restart of the LPAR's correlating Common Services GSS address space resolved the S0D3-13 abend in the NSIGHTDC module.