Vantage - SAMS abending with a S0C7 DFSMShsm
search cancel

Vantage - SAMS abending with a S0C7 DFSMShsm

book

Article ID: 201421

calendar_today

Updated On:

Products

Vantage Storage Resource Manager GRAPHICAL MANAGEMENT INTERFACE

Issue/Introduction

             
                                                                  
 CCSR010E GENESTAE S0C7 at 1E545A60 LMOD GENFLT01 CSECT GENFLT01 +001A60 SAMS 
 CCSR021I OWNER = CA Vantage SRM R14.0                                        
 CCSR022I MODULE = GENFLT01 FMID = CCTUE00 RMID = CCTUE00                     
 CCSR060I BREAKING EVENT ADDRESS: 00000000 1E545A20                           
 CCSR061I PSW: 07852001 80000000 00000000 1E545A60                            
 ILC: 06 INTERRUPT CODE: 07                                                   
 COMPLETION CODE S0C7 REASON CODE 00000000                                    
 DATA AT PSW 1E545A5A : F9FFD139 D149A7F4 000BB904                            
 ...                                                                          
 VKG0831E Calling CSECT=OBC06106 (STKPGMNM)             Offset=00000171       
 VKG0832E Calling LoadModule=OBC06106 E.P.Adr.=1E7B0481 Offset=000006DA       
 VKG0833E Data at Ofs=0C00160C EF50F0D0 48D503D0                              

Environment

Release : 14.0

Component : CA Vantage Storage Resource Manager

Resolution

The ST15183 test apar has been written to fix this problem. To obtain this test apar, the technical support of broadcom should be contacted.

While waiting for the ST15183 to be applied,  the OBJ06106 logging script should be disabled to prevent the S0C7 abend.