S0C1 abend during a Disk backup of the open files with VSVERIFYA
search cancel

S0C1 abend during a Disk backup of the open files with VSVERIFYA

book

Article ID: 200876

calendar_today

Updated On:

Products

Disk Backup and Restore - MVS DISK BACKUP AND RESTORE- ADD-ON OPTIO DISK BACKUP AND RESTORE

Issue/Introduction

For z/OS 2.4,  DISK 12.5 maintenance applied:

With SYSPARM VSVERIFY set to A, running a BACKUP or ARCHIVE of an in-use data set defined with the applicable share option less than 3 results in the data set being bypassed for processing.                                      
                                                                             
The following messages appear on the joblog:                                                                 
                                             
IEC161I 052(013,-jobname1-)-084,-jobname2-,DMS     -stepname-,VSAM,,,        
IEC161I -data set name-,                                                     
IEC161I -catalog name-                                                       
...                                                                          
ADSVS038 9999 ESTAE EXIT ENTERED DURING VERIFY FOR VSAM DDNAME=VSAM          
ADSVS038 SYSTEM COMPLETION CODE=00C1 USER COMPLETION CODE= 0                 
ADSVS064 2515 THE FOLLOWING CLUSTER COULD NOT BE OPENED AFTER A              
         VERIFY - DATA SET BYPASSED: -data set name-                         
ADSVS060 0394 -data set name- WAS NOT ARCHIVED DUE TO PREVIOUS ERROR         
                                                                             

Environment

Release : Disk Backup and Restore 12.5

Resolution

Apply the PTF SO15078 to fix the problem.