Client Automation - caf_writePipe failed to write sig to pipe - (232) The pipe is being closed
search cancel

Client Automation - caf_writePipe failed to write sig to pipe - (232) The pipe is being closed

book

Article ID: 200737

calendar_today

Updated On:

Products

CA Client Automation CA Client Automation - IT Client Manager

Issue/Introduction

After a reboot of Domain Manager command caf status does not work and fails with message :

Failed to connect to the local caf service.

 

In TRC_CF_CAF_SERVICE_*.log following error appears :

240920-08:16:10.6936750L|001488|000005f0|CAF_SERVIC|        |        |000000|ERROR  | caf_writePipe: failed to write sig to pipe: : (232) The pipe is being closed.  
240920-08:16:10.6937582L|001488|000005f0|CAF_SERVIC|cafutils|cafutils|000000|ERROR  | caf_writePipe: Some error occured

Environment

Client Automation 14.*

Resolution

On some Windows environment it may necessary to delay the start of caf service to let time to others Windows services to initialize.

This could be done with 2 methods :

- GUI method in Windows Services :

 

- Command Line method :

sc config caf start= delayed-auto