Description:
CA Common Services SMP/e APPLY CHECK or APPLY of maintenance (PTF RO50738 and RO57237 for example) is failing with GIM65802E messages.
GIM65802E ** MODULE CAS0SVER IS NEEDED TO BUILD THE FOLLOWING LOAD MODULES FOR SYSMOD RO50738 BUT IS NOT FOUND. THE MODULE IS NOT IN DISTRIBUTION ZONE CAID, AND SYSMOD RO43561 WHICH LAST REPLACED THE MODULE IS NOT IN THE SMPPTS. GIM65802E ** MODULE CAMSMDS IS NEEDED TO BUILD THE FOLLOWING LOAD MODULES FOR SYSMOD RO57237 BUT IS NOT FOUND. THE MODULE IS NOT IN DISTRIBUTION ZONE CAID, AND SYSMOD RO44137 WHICH LAST REPLACED THE MODULE IS NOT IN THE SMPPTS.
The above message can show up for other SYSMODs and Modules as well.
Solution:
The CA Common Services base product must be ACCEPTed in SMP/e before applying additional maintenance.
SAMPJCL job AW05ACC can be used to do the ACCEPT.