GJMFTSR1 receives ABEND=S000 U0302 along with TRAC608E  LOGIC ERROR
search cancel

GJMFTSR1 receives ABEND=S000 U0302 along with TRAC608E  LOGIC ERROR

book

Article ID: 199319

calendar_today

Updated On:

Products

Jobtrac Automic Automation Intelligence

Issue/Introduction

IEF450I JOBTRACn - ABEND=S000 U0302 REASON=00000000

TRAC608E  LOGIC ERROR IN GJMFTSR1.  AT ADDERR
TRAC638E JMF SERVICES ERROR. COMMAND ERROR

Environment

Release : 11.0

Component : JOBTRAC

Resolution

To address the logic error in GJMFTSR1,  increase  'JMFTABLE' table in parmlib member JOBTRA00.

A 'S VINIT3,PARM=BACK' needs to be issued to invoke the change, to back out the JOBTRAC internals.

Additional Information

The JMFTABLE option specifies the number of entries in the JMF table. The default is 1000 and the ECSA usage is approximately 140 KB with this value.

Specifying 2000 would use approximately 280 KB (and so on) .