DX Spectrum - SPC-DBS-23007: This save file cannot be loaded by version
book
Article ID: 199225
calendar_today
Updated On:
Products
Spectrum
Network Observability
Issue/Introduction
When attempting to load a SpectroSERVER database save from the command line, I am seeing the following error:
../SS-Tools/SSdbload -il /home/spectrum/33128781/20220530_1900.SSdb
SPC-DBS-23007: This save file cannot be loaded by version 23.2.8.000 of Spectrum.
It was saved as version 23.2.6.000 .
Environment
Release : All
Component : Spectrum Core / SpectroSERVER
Resolution
Restoring the SpectroSERVER database backup (SSdb) taken from a different Spectrum release is not allowed.
In the above example, the SSdb was from Spectrum 23.2.6.000 and trying to be loaded into Spectrum 23.2.8.000.