SpectroWatch threshold alarm not clearing when threshold reset value is met

book

Article ID: 198769

calendar_today

Updated On:

Products

CA Spectrum

Issue/Introduction

SpectroWatch threshold alarm not clearing when threshold reset value is met

Cause

If the attribute used in the watch expression is a table (instance) attribute, the same instance value that violated the threshold is used for the threshold reset.

Environment

Release : Any

Component : Spectrum Core / SpectroSERVER

Resolution

To verify:

1. Select the model where the threshold was violated and created the alarm.

2. Click on the Attributes tab

3. Find and select the attribute used in the watch expression.

4. Click on blue table link. The following is an example:

5. From the event, compare the instance value with the value seen in the table

Additional Information

Please reference the "Watches" section of the documentation for more information.