The following error is seen when running the NewMM.pl script after a Spectrum upgrade
Error Code = 1
An error occurred writing one or more port attributes
Model Handle: 0x1d02f0
Attr ID: 0x11dd8
Failure
Release : Any
Component : Spectrum Core / SpectroSERVER
For this error, the NewMM.pl script could not write a value to attribute id 0x11d88 which is the ok_to_poll attribute on an interface model.
In the users environment, there is a Global Collection that contains this interface model at model handle 0x1d02f0. The Global Collection has a Policy attached setting the value of the ok_to_poll attribute id 0x11dd8. Since this attribute is controlled by the Policy, the Policy is preventing the NewMM.pl script from writing to this attribute.
This error can be ignored since it is the Policy preventing the NewMM.pl script from writing to the ok_to_poll attribute id 0x11dd8.
Please reference the "Policy Manager" section of the documentation for more information.