Runtime error: Could not create data sequence 'FILETRANSFER'. Status: '0000001820', return code: '0000000000'.

book

Article ID: 197935

calendar_today

Updated On:

Products

CA Automic Workload Automation - Automation Engine CA Automic One Automation CA Automic Operations Manager CA Automic Oracle

Issue/Introduction

When attempting to run a task that utilizes a PREP_PROCESS and UNIXCMD, you see the following error(s):

8/24/2020 06:55:38 PM
 
U00010038 Runtime error: Could not create data sequence 'FILETRANSFER'. Status: '0000001820', return code: '0000000000'.
8/24/2020 06:55:37 PM
 
U00029003 Cannot open file '/home/automic/EAACLVXI.TXT(ReadFileAuthority())', error code '2', error description: 'No such file or directory'.
8/24/2020 06:55:37 PM
 
U00011000 'REPORT' (RunID: '0001119021') could not be started on 'UNIX01'. See next message.
8/24/2020 06:55:37 PM
 
U00011003 Job 'EVENT.UNIXCMD' (RunID '0001122091') on Host 'UNIX01' aborted (return code='0002'). Remote ID=16527

Cause

This is due to the command being run returning no results; for example, an ls of a path/file combination that does not exist (ls /home/automic/test/*nofiles*) can cause this.

Environment

Release : 12.3

Component : AUTOMATION ENGINE

Resolution

Confirm the command being issues to the UNIXCMD is valid and has a valid return.