After upgrading to IMS 15.2, the ACF2 SHOW STATE and SHOW STORAGE still show IMS 15.1
JOB R nnn,/ACF SHOW STORAGE.
JOB DFS000I ACF2/IMS RELEASE - r16 SP00 IMS RELEASE - 15.1
JOB DFS000I STORAGE - PROGRAM ====> 96032
JOB DFS000I STORAGE - ABOVE THE LINE ====> 73090
JOB DFS000I STORAGE - BELOW THE LINE ====> 28928
JOB R nnn,/ACF SHOW STATE.
JOB DFS000I ACF2/IMS RELEASE - r16 SP00 IMS RELEASE - 15.1
Is this a bug?
Release : 16.0
Component : CA ACF2 for z/OS
This is not a bug. The release 15.2 of IMS was only an upgrade in certain areas. IBM documents this:
"The IMS installed level is updated to 15.2 in the SCDINLVL control block field. Output locations, including those in the preceding list, that reference the SCDINLVL control block field are updated to 15.2. However, because the IMS installed level that is specified in the SSCDIMSR control block field and the DFSLEV constant is not changed, the output locations that reference SSCDIMSR or DFSLEV will continue to display 15.1 even after you apply PH16682/xxx."
For more information on the IBM changes: https://www.ibm.com/support/knowledgecenter/SSEPH2_15.2.0/com.ibm.ims152.doc.rpg/ims_mig_release.htm