U2290 Abend Using 3rdParty Unload on FastPath DB with IMSHRINK

book

Article ID: 197042

calendar_today

Updated On:

Products

CA Compress Data Compression (IMS Tools)

Issue/Introduction

A third-party vendor tool is being used to unload an IMS Fast-path database. The fast path database is using IMSHRINK. Performing the unload, an ABEND CODE: U2990 REASON CODE: X'329A9900' is encountered. 

 

Environment

Release : 20.0

Component : CA-Compress Data Compression for IMS

Resolution

The U2990 abend is caused by a zero PST or SCD address (SCD is obtained from PSTSCDAD field, that is +1D4 in PST structure).

Additional Information

The U2990 abend is caused by missing PST or SCD.