CA-1 Tape Management TMSUDSNB RC=12 - SYSTEM SHUTDWN VALUE REQUIRED-INCORRECT SHUTDWN VALUE SPECIFIED
search cancel

CA-1 Tape Management TMSUDSNB RC=12 - SYSTEM SHUTDWN VALUE REQUIRED-INCORRECT SHUTDWN VALUE SPECIFIED

book

Article ID: 196336

calendar_today

Updated On:

Products

CA 1 Flexible Storage CA 1 Tape Management - Copycat Utility CA 1 Tape Management - Add-On Options

Issue/Introduction

Running TMSUDSNB with the following SYSIN and getting RC=12.
                   
//SYSIN DD *                                                          
SHUTDWN=shutdown password                                                   
DSNB nnnnnn,NOVER                                                           
REP NEXT=nnnnn                                                        
/*                    

TMSUDSNB output shows
 xxxxx     SYSTEM SHUTDWN VALUE REQUIRED-INCORRECT SHUTDWN VALUE SPECIFIED

Environment

Release : 14.0

Component : CA 1 Tape Management

Resolution

CIRCUMVENTION: rerun  TMSUDSNB and specify 2 equal signs instead of 1 after the SHUTDWN control statement;
SHUTDWN== instead of SHUTDWN= followed by the SHUTDWN value from your TMOOPTxx member

Permanent solution is to apply CA 1 APAR RO98303