CA Fastload Using USS Pipe Fails on 254 part table PFL3019E S878 PFL0206E PFL0207E

book

Article ID: 195746

calendar_today

Updated On:

Products

CA Database Analyzer for DB2 for z/OS CA Fast Unload for DB2 for z/OS CA Fast Check for DB2 for z/OS CA Fast Index for DB2 for z/OS CA Fast Load for DB2 for z/OS CA Rapid Reorg for DB2 for z/OS CA Database Management for DB2 for z/OS - Utilities Suite

Issue/Introduction

Running Fast Load on a 254 part object using USS Pipe and ENABLE-PFL20  YES parm  may fail with:
IEA705I ERROR DURING GETMAIN SYS CODE = 878-10
PFL3019E - ESTAE intercepted in CSECT FLAUTWTR - ABEND code X'840C4000'  
PFL0206E - FASTLOAD application did not complete successfully            
PFL0207E - TS_Write Task ECB: X'000C4000'   Return Code: X'00000010'     
 

Environment

Release : 20.0

Component : CA Fast Load for DB2 for z/OS

Resolution

ENABLE-PFL20 YES is a hidden parameter which enables the process of;

"removal of restrictions when having mixed partition data in multiple input files when multiple SYSULDS are used."

We recommend you avoid using that ENABLE-PFL20 YES switch, set it to NO.

 

Glad this resolved the case.