Issue/Introduction

When I rerun CAS9 due to update of CAOETABL PRTLIB DSN, CAMR951E generated.
                                     
//A EXEC PGM=CAVHINIT                                                 
//RIMPARM DD *                                                        
PRODUCT(CA INTERTEST/SYMDUMP) VERSION(VHB0) INIT(CAVHINIT) PARM(220)  

 CAVH003I CAVHCONF LOADED
 CAVH004I PRODUCT INTENT: DYNAMIC OPTION ON
 CAVH004I PRODUCT INTENT: INTBAT  OPTION ON
 CAVH004I PRODUCT INTENT: SYMDUMP OPTION ON
 CAVH004I PRODUCT INTENT: SYMCICS OPTION ON
 CAVH004I PRODUCT INTENT: INTCICS OPTION ON

 CAMR951E VALUE OUT OF RANGE (MUST BE 200-255)

 CAPC033I CA SYMDUMP BATCH     RTL REFRESH REQUESTED.
 CAPC034I CA SYMDUMP BATCH     RTL REFRESH COMPLETED.
 CAPE005I INITIALIZATION COMPLETED
 CAPE004I SQA TABLE RESIDES IN CORE AT ADDRESS  91713000

 

Environment

Release : 11.0

Component : CA SymDump Batch

Resolution

Initialize product(or runtime) require to execute CAIRIM instead CAVHINIT.

//A EXEC PGM=CAIRIM                                                 
//PARMLIB  DD *                                                        
PRODUCT(CA INTERTEST/SYMDUMP) VERSION(VHB0) INIT(CAVHINIT) PARM(220)  
/*