One of the IDB2 DC's terminates with a AbendS0C4

book

Article ID: 195111

calendar_today

Updated On:

Products

CA Bind Analyzer for DB2 for z/OS CA SQL-Ease for DB2 for z/OS CA Sysview Performance Management Option for DB2 for z/OS CA Plan Analyzer for DB2 for z/OS CA Subsystem Analyzer for DB2 for z/OS CA Database Management for DB2 for z/OS - Performance Suite CA Database Management for DB2 for z/OS - SQL Performance Suite CA Detector for DB2 for z/OS CA-Insight Performance Monitor for DB2 UDB for z/OS

Issue/Introduction

Sysview for DB2 (IDB2) part of the CE-APM to IDB2 interface to provide DB2 metrics to the Wily (CE-APM) user interface terminates with an AbendS0C4.

Cause

IBM bug.  IBM APAR PH26655 will correct this condition.

Environment

Release : 19.0

Component : CA Insight Database Performance Monitor for DB for z/OS

Resolution

DB2, calling its routine DSNWARDA, tried to write data past the buffer provided by IDB2.  This caused the S0C4 abend.  