GSV2808I Specified log stream name not defined in the LOGR policy. CEITRACE LOGSTREAM NOT FOUND on CEITLOG
search cancel

GSV2808I Specified log stream name not defined in the LOGR policy. CEITRACE LOGSTREAM NOT FOUND on CEITLOG

book

Article ID: 195088

calendar_today

Updated On:

Products

SYSVIEW Performance Management NXBRIDGE - SYSVIEW/ENDEVOR

Issue/Introduction

CEITRACE definition:
Definition Name     CICSTEST

Match Criteria                            Attributes
Jobname             CICSTEST              Status           DISABLED
Transaction         ITST____              Trace Level      DETAIL__
Terminal            =_______              Match Limit      1_______
Userid               job_____

CEITLOG error:
 Command ====>
 GSV2808I Specified log stream name not defined in the LOGR policy. ---
 LogStream NOT.DEFINED                     Retention
 Available                              to
 Searched                               to
 Displayed                              to
 Options   Lines          Limit          Period
 ----------------------------------------------------------------------
 Cmd  Jobname  Date       Time     Tran     Task# Program  Term LUName

SYSVISER STC or TSO USERID Message at time of failure:
13.15.28 TSU06151  IXG231I IXGCONN REQUEST=CONNECT TO LOG STREAM NOT.DEFINED DID NOT  322
   322             SUCCEED FOR JOB job.  RETURN CODE: 00000008  REASON CODE: 0000080B
   322             DIAG1: 00000000  DIAG2: 00000000  DIAG3: 00000000  DIAG4: 00000000
13.15.30 TSU06151  IXG231I IXGCONN REQUEST=CONNECT TO LOG STREAM NOT.DEFINED DID NOT  323
   323             SUCCEED FOR JOB job.  RETURN CODE: 00000008  REASON CODE: 0000080B
   323             DIAG1: 00000000  DIAG2: 00000000  DIAG3: 00000000  DIAG4: 00000000

Unable to determine logname(s) missing
SYS9 logstream names:

  2      LIST LOGSTREAM NAME(SYSV*.SYS9*) DETAIL(NO)
LOGSTREAM NAME(SYSV.AUDIT.ADTT.SYS9) STRUCTNAME() LS_DATACLAS()
LOGSTREAM NAME(SYSV.CICSLOGR.SYSD.xxxx) STRUCTNAME() LS_DATACLAS()
LOGSTREAM NAME(SYSV.CICSLOGR.TRAN.xxxx) STRUCTNAME() LS_DATACLAS()
LOGSTREAM NAME(SYSV.CICSLOGR.TSUM.xxxx) STRUCTNAME() LS_DATACLAS()
LOGSTREAM NAME(SYSV.CICSLOGR.XLOG.xxxx) STRUCTNAME() LS_DATACLAS()
LOGSTREAM NAME(SYSV.IMSLOGR.IMRS.xxxx) STRUCTNAME() LS_DATACLAS()
LOGSTREAM NAME(SYSV.IMSLOGR.IMTR.xxxx) STRUCTNAME() LS_DATACLAS()
LOGSTREAM NAME(SYSV.SMFDATA.SMFD.xxxx) STRUCTNAME() LS_DATACLAS()
LOGSTREAM NAME(SYSV.SYSDATA.PLOT.xxxx) STRUCTNAME() LS_DATACLAS()
LOGSTREAM NAME(SYSV.SYSDATA.XLOG.xxxx) STRUCTNAME() LS_DATACLAS()
LOGSTREAM NAME(SYSVIEW.AUDIT.ADTT.xxxx) STRUCTNAME() LS_DATACLAS()
LOGSTREAM NAME(SYSVIEW.CICSLOGR.EITL.xxxx) STRUCTNAME() LS_DATACLAS()
LOGSTREAM NAME(SYSVIEW.CICSLOGR.SYSD.xxxx) STRUCTNAME() LS_DATACLAS()
LOGSTREAM NAME(SYSVIEW.CICSLOGR.TRAN.xxxx) STRUCTNAME() LS_DATACLAS()
LOGSTREAM NAME(SYSVIEW.CICSLOGR.TSUM.xxxx) STRUCTNAME() LS_DATACLAS()
LOGSTREAM NAME(SYSVIEW.CICSLOGR.XLOG.xxxx) STRUCTNAME() LS_DATACLAS()
LOGSTREAM NAME(SYSVIEW.IMSLOGR.IMRS.xxxx) STRUCTNAME() LS_DATACLAS()
LOGSTREAM NAME(SYSVIEW.IMSLOGR.IMTR.xxxx) STRUCTNAME() LS_DATACLAS()
LOGSTREAM NAME(SYSVIEW.SMFDATA.SMFD.xxxx) STRUCTNAME() LS_DATACLAS()
LOGSTREAM NAME(SYSVIEW.SYSDATA.PLOT.xxxx) STRUCTNAME() LS_DATACLAS()
LOGSTREAM NAME(SYSVIEW.SYSDATA.XLOG.xxxx) STRUCTNAME() LS_DATACLAS()




Environment

Release : 16.0

Component : SYSVIEW

Resolution

The Log Stream Datasets are defined via the INST0040-INST0046 jobs. The CEITLOG is specifically defined in INST0044, and is called the EITL data set. To avoid the NOT.DEFINED error condition for any of the log streams, update the CICSLOGR and LGLOOKUP parmlib members to point to either a valid Log Stream name/definition or to NONE. If you do not define the dataset, and leave the LOGSTREAM-CICSEITL-NAME, for example, set to the default value, you will see the NOT.DEFINED error.