Brocade switch and Foundry Iron models are not appearing in the Spectrum Chassis Manager folder

book

Article ID: 194841

calendar_today

Updated On:

Products

CA Spectrum CA eHealth

Issue/Introduction

Brocade switch and Foundry Iron models are not appearing in the Spectrum Chassis Manager folder. Specifically:

Foundry Iron ICX7450-48 SPS08030e with a sysObjecyID of 1.3.6.1.4.1.1991.1.3.48.8.1

Brocade switch FCXIronStackSw with a sysObjectID of 1.3.6.1.4.1.1991.1.3.48.2.1

Cause

As discussed in the "Support for Chassis Devices" section of the documentation, the Spectrum Chassis Manager supports the following mibs:

The jnxBoxAnatomy in the JUNIPER-MIB for Juniper devices

The ENTITY-MIB for all other devices.

A check of these two devices showed the following:

The Brocade switch FCXIronStackSw with a sysObjectID of 1.3.6.1.4.1.1991.1.3.48.2.1 dis not support the ENTITY-MIB.

The Foundry Iron ICX7450-48 SPS08030e with a sysObjecyID of 1.3.6.1.4.1.1991.1.3.48.8.1 does not fully support the ENTITY-MIB. It supports the Physical Entities but not the Logical Entities.

Environment

Release : Any

Component : Spectrum Core / SpectroSERVER

Resolution

The Spectrum Chassis Manager is functioning as designed for the devices.