Receiving hundreds of messages for one of the Sysview Performance Management Option for Db2 for z/OS Data Collectors.
DBG72037E D2TC 06:15:19 ERROR EXECUTING DISPLAY GROUP COMMAND FOR SUBSYSTEM D2TC
DBG72037E D2TC 06:15:19 ERROR EXECUTING DISPLAY GROUP COMMAND FOR SUBSYSTEM D2TC
DBG72037E D2TC 06:15:19 ERROR EXECUTING DISPLAY GROUP COMMAND FOR SUBSYSTEM D2TC
DBG72037E D2TC 06:15:19 ERROR EXECUTING DISPLAY GROUP COMMAND FOR SUBSYSTEM D2TC
How to resolve the recursive messages?
Release: 20.0
Component: Sysview Performance Management Option for Db2 for z/OS
To eliminate the recursive DBG72037E messages, inactivate the following "Subsystem" Exceptions:
ACTIVE **** High percent of CF list entries in use: &VALUEXX
ACTIVE **** High percent of SCA in use: &VALUEXX
The above Exceptions at generates the Display Group Commands.