After applying JCLCheck and/or CA1 TMS maintenance, the following message is generated when validating a JCL member containing tape data sets:
CAY6474E PRODUCT "TMS" VERS "nnnn" NOT INITIALIZED BY CAIRIM
or
CAY6150W 'TMS' ROUTINES HAVE NOT BEEN LINKED, 'TMS' OPTION SUPPRESSED
Release : 12.0
Component : JCLCheck workload Automation
. If CA 1 TMS maintenance is recently applied, re-apply JCLCheck usermod MZ1C048 (with the SMP REDO option) to relink the JCLCheck CA 1 interface module with the latest CA 1 macro library.
. Since the release of JCLCheck PTF RO91113, the JCLCheck runtime option TMS(nn) needs to be coded simply as TMS. Therefore ensure that JCLCheck runtime option TMS is specified and not TMS(nn).
Note: If runtime option TMS(nn) is specified as a default option, JCLCheck usermod MZ1C024 needs to re-applied to change TMS(nn) to TMS. To determine the default options, review the JCLCheck job listing, and look for "DEFAULT PARAMETERS:".