How to install maintenance for cics 5.5
search cancel

How to install maintenance for cics 5.5

book

Article ID: 194254

calendar_today

Updated On:

Products

DADS Plus

Issue/Introduction

How can I install these fixes?

RO10396.DATA    
RO10396L.LOADLIB
RO10396M.MACLIB 
RO31901.DATA    
RO31901.LOADLIB 
RO53206.DATA    
RO53206.LOADLIB 
RO70937.DATA    
RO70937.LOADLIB 

Environment

Release : 4.0

Component : CA DADS Plus

Resolution

RO10396 install step:

 1) THIS PTF SUPERSEDES AND INCLUDES ALL FIXES WRITTEN  FOR     
    CA-DADS/PLUS-MVS  SINCE GENLEVEL 0507 SERVICE PACK 2 AS     
    OF AUGUST 07 2009, BUT INTRODUCES NO NEW MAINTENANCE. IT    
    CORRECTS PTF CONSTRUCTION ERRORS IN EXISTING PUBLISHED      
    PTFS SUCH AS THOSE THAT MAY REQUIRE USE OF BYPASS(ID).      
    THIS PTF IS SUGGESTED FOR ALL USERS BUT WILL BE OF          
    PARTICULAR INTEREST TO CUSTOMERS APPLYING MAINTENANCE       
    VIA CA MAINFRAME SOFTWARE MANAGER (MSM), AS MSM DOES NOT 
    SUPPORT BYPASS(ID).                                      
                                                             
 2) DOWNLOAD THE RO10396L.XMIT, RO10396M.XMIT                
    AND SMP CONTROL CARDS RO10396.TXT.                       
                                                             
 3) BINARY TRANSFER THE RO10396.XMIT FILES TO TSO INTO       
    PRE-ALLOCATED SEQUENTIAL DATASETS WITH THE FOLLOWING     
    ATTRIBUTES:                                              
       DCB=(RECFM=FB,BLKSIZE=3200,LRECL=80)                  
                                                             
 4) RECEIVE THE FILES:                                       
     TSO RECEIVE INDATASET('UPLOAD.FILE.RO10396L.XMIT')      
     WHEN PROMPTED FOR PARMS, THEN ENTER:                    
     DATASET('YOURHLQ.RO10396L.LOADLIB')                     
                                                             
     TSO RECEIVE INDATASET('UPLOAD.FILE.RO10396M.XMIT')      
     WHEN PROMPTED FOR PARMS, THEN ENTER:                    
     DATASET('YOURHLQ.RO10396M.MACLIB')                      
                                                             
 5) INSTALL RO10396 USING SMP/E AND INSERTING                
    THE FOLLOWING DD CARDS JUST BEFORE THE SMPCNTL DD:       
                                                        
    //RO10396L  DD DSN=YOURHLQ.RO10396.LOADLIB,DISP=SHR 
    //RO10396M  DD DSN=YOURHLQ.RO10396.MACLIB,DISP=SHR  
                                                        
6) AFTER RO10396 IS APPLIED, BRING UP CICS AND TEST.

RO53206 install step:

 1) DOWNLOAD THE RO53206.XMIT FILE                       
    AND SMP CONTROL CARDS RO53206.TXT.                   
                                                         
 2) BINARY TRANSFER THE RO53206.XMIT FILE TO TSO INTO A  
    PRE-ALLOCATED SEQUENTIAL DATASET WITH THE FOLLOWING  
    ATTRIBUTES:                                          
       DCB=(RECFM=FB,BLKSIZE=3200,LRECL=80)              
                                                         
 3) RECEIVE THE FILE:                                    
     TSO RECEIVE INDATASET('UPLOAD.FILE.RO53206.XMIT')   
     WHEN PROMPTED FOR PARMS, THEN ENTER:                
     DATASET('YOURHLQ.RO53206.LOADLIB')                  

 4) INSTALL RO53206 USING SMP/E AND INSERTING                  
    THE FOLLOWING DD CARD JUST BEFORE THE SMPCNTL DD:          
                                                               
     //RO53206L  DD DSN=YOURHLQ.RO53206.LOADLIB,DISP=SHR       
                                                               
 5) AFTER RO53206 IS APPLIED, BRING UP CICS AND TEST.          
                                                               
          ***NOTE***  RETAIN THE PRINTED OUTPUT FOR REFERENCE. 
                                                               
                                                               
          ***NOTE***  YOU MUST REINSTALL THE ADVANTAGE CA-DADS 
                      PLUS FOR CICS SVC AFTER APPLICATION OF   
                      THIS PTF. REFER TO YOUR INSTALLATION     
                      GUIDE FOR DETAILED INSTRUCTIONS.         

RO31901 install step:

 1) DOWNLOAD THE RO31901.XMIT FILE                         
    AND SMP CONTROL CARDS RO31901.TXT.                     
                                                           
 2) BINARY TRANSFER THE RO31901.XMIT FILE TO TSO INTO A    
    PRE-ALLOCATED SEQUENTIAL DATASET WITH THE FOLLOWING    
    ATTRIBUTES:                                            
       DCB=(RECFM=FB,BLKSIZE=3200,LRECL=80)                
                                                           
 3) RECEIVE THE FILE:                                      
     TSO RECEIVE INDATASET('UPLOAD.FILE.RO31901.XMIT')     
     WHEN PROMPTED FOR PARMS, THEN ENTER:                  
     DATASET('YOURHLQ.RO31901.LOADLIB')                    

 4) INSTALL RO31901 USING SMP/E AND INSERTING                              
    THE FOLLOWING DD CARD JUST BEFORE THE SMPCNTL DD:                      
                                                                           
     //RO31901L  DD DSN=YOURHLQ.RO31901.LOADLIB,DISP=SHR                   
                                                                           
 5) AFTER RO31901 IS APPLIED, BRING UP CICS AND TEST.                      
                                                                           
          ***NOTE***  RETAIN THE PRINTED OUTPUT FOR REFERENCE.             
                                                                           
                                                                           
          ***NOTE***  YOU MUST REINSTALL THE ADVANTAGE CA-DADS             
                      PLUS FOR CICS SVC AFTER APPLICATION OF               
                      THIS PTF. REFER TO YOUR INSTALLATION                 
                      GUIDE FOR DETAILED INSTRUCTIONS.                     

RO70937 install step:

 1) DOWNLOAD THE RO70937.XMIT FILE                           
    AND SMP CONTROL CARDS RO70937.TXT.                       
                                                             
 2) BINARY TRANSFER THE RO70937.XMIT FILE TO TSO INTO A      
    PRE-ALLOCATED SEQUENTIAL DATASET WITH THE FOLLOWING      
    ATTRIBUTES:                                              
       DCB=(RECFM=FB,BLKSIZE=3200,LRECL=80)                  
                                                             
 3) RECEIVE THE FILE:                                        
     TSO RECEIVE INDATASET('UPLOAD.FILE.RO70937.XMIT')       
     WHEN PROMPTED FOR PARMS, THEN ENTER:                    
     DATASET('YOURHLQ.RO70937.LOADLIB')                      
                                                             
 4) INSTALL RO70937 USING SMP/E AND INSERTING                
    THE FOLLOWING DD CARD JUST BEFORE THE SMPCNTL DD:        
                                                             
     //RO70937L  DD DSN=YOURHLQ.RO70937.LOADLIB,DISP=SHR        
                                                                
 5) AFTER RO70937 IS APPLIED, BRING UP CICS AND TEST.           
                                                                
          ***NOTE***  RETAIN THE PRINTED OUTPUT FOR REFERENCE.  
                                                                
                                                                
          ***NOTE***  YOU MUST REINSTALL THE ADVANTAGE CA-DADS  
                      PLUS FOR CICS SVC AFTER APPLICATION OF    
                      THIS PTF. REFER TO YOUR INSTALLATION      
                      GUIDE FOR DETAILED INSTRUCTIONS.