Ca Common Services - CAS 9 procedure does not start - ABEND=S0C1 U0000 REASON=00000001 
search cancel

Ca Common Services - CAS 9 procedure does not start - ABEND=S0C1 U0000 REASON=00000001 

book

Article ID: 194101

calendar_today

Updated On:

Products

COMMON SERVICES FOR Z/OS 90S SERVICES Common Services

Issue/Introduction

Starting CAS9 (after bringing online new IBM Storage Unit) , getting the following abend:

IEF450I CAS9 CAS9 - ABEND=S0C1 U0000 REASON=00000001 

Environment

Release : ANY

Component : CCS390 - CA COMMON SERVICES FOR Z/OS

Resolution

picking up 15.0 modules unintentionally

Additional Information

This was a case of mixed maintenance. Attempts to create a new linklist and refreshing LLA would not correct the issue. 

What finally corrected the issue was the 15.0 Common Services load libraries were removed from the boot up linklist and an IPL was performed.