CA JCLCHECK - IBM Tivoli Workload Scheduler (TWS) interface - resolving TWS variables - getting CAY6A019E, EQQZ067E, EQQZ067I FURTHER STATEMENT PROCESSING STOPPED    
search cancel

CA JCLCHECK - IBM Tivoli Workload Scheduler (TWS) interface - resolving TWS variables - getting CAY6A019E, EQQZ067E, EQQZ067I FURTHER STATEMENT PROCESSING STOPPED    

book

Article ID: 193895

calendar_today

Updated On:

Products

JCLCheck Workload Automation UNICENTER JCLCHECK COMMON COMPONENT

Issue/Introduction

Running the JCLCheck program CAZ1PRES to resolve IBM Tivoli Workload Scheduler (TWS) variables and getting the following error messages:

CAY6A019E RESOLUTION PROCESSOR ERROR; FUNCTION=INIT, RC=0008, MESG=ERROR ON 'INIT OPCS ' REQUEST,TWS RC=0000008                     
EQQZ067E COMMAND SYNTAX ERROR: ************************************************************************  
EQQZ067I FURTHER STATEMENT PROCESSING STOPPED          

Environment

Release : 12.0

Component : CA JCLCheck workload Automation

Resolution

Remove the line of asterisks in the EQQYRPRM member. This is causing the EQQZ067E error message. 

Additional Information

From the IBM TWS error message manual

EQQZ067E COMMAND SYNTAX ERROR: CARD FURTHER STATEMENT PROCESSING STOPPED

Explanation:  The statement contains a syntactically incorrect command.

System action:  No more statements will be processed. The program is terminated with return code 8.